Qualifying a Second Source for Precast Concrete Electrical Boxes: C-C 60 mm Wall Boxes vs. C-C 70 mm and 67 mm Ceiling Boxes

Short answer for precast plant procurement and engineering: Before comparing prices or requesting samples for cast-in electrical installation boxes, separate the catalogue range by device fixing centre and element type. In the Glob-el 2026 catalogue (pp. 40–55), precast wall and element boxes use a 60 mm device screw centre (M3) (ETM780S, ETM784S, ETM812S, ETM850S), concrete ceiling and roof boxes use a 70 mm screw centre (M4, max. 15 kg load) (ETM834S, ETM837S), and multi-way concrete connection boxes use a 67 mm screw centre (ETM931S, ETM835S).

Once concrete is poured around a box on a circulation pallet or tilting table, a shifted box or a cement-fouled conduit entry becomes a costly repair. This four-point engineering checklist helps precast concrete plants and electrical distributors qualify a second source systematically. For application context, see Precast Concrete Plants and the Concrete & Precast Boxes family page.

1. Step One: Separate C-C 60 mm Wall Boxes from C-C 70 mm / 67 mm Ceiling and Connection Boxes

A frequent mistake in multi-country tenders is grouping all yellow cast-in boxes under one generic line item. Always lock the screw centre, load rating and conduit interface against the exact element drawing first:

Catalogue Group Model Reference Screw Centre & Thread Documented Dimensions (2026 Catalogue) Conduit Entries & Cover Mould Fixing & Casting Spec
Precast wall / element box (single) ETM780S C-C 60 mm (M3), gang 71 mm Ø71 mm body, depth 60.5 mm (drawing envelope 71 × 103 × 60 mm) 1 × twin 2ר20 mm top inlet (ETM793S), with locking springs & plugs Magnet on steel mould or BULO holder; PP, IP30, up to +90 °C during casting
Precast wall / element box (plugged dual-diameter) ETM784S C-C 60 mm (M3), gang 71 mm Ø71 mm body, depth 60.5 mm (drawing labels 71 × 104 × 75 mm) Plugged twin 2ר16/20 mm top inlet (ETM788S) Magnet on steel mould; PP, IP30, up to +90 °C during casting
Precast wall / element box (double twin-inlet) ETM812S C-C 60 mm (M3) Drawing envelope 71 × 103 × 76 mm (30 mm side label) 2 × twin 2ר20 mm plugged inlet assemblies + cover ETM794S Precast concrete element; PP, IP30, up to +90 °C during casting
Precast concrete box with BULO & EPD ETM850S C-C 60 mm Outer Ø73.5 / inner Ø56.5 mm, overall height 123 mm 1–2 × Ø20 mm conduit entries (ETM792S inlet); ETM850S-1 without BULO With BULO holder; halogen-free PP, IP30, verified EPD (HUB-6177)
Shallow hollow-wall & concrete casting box ETM750S C-C 60 mm (ST2.9), gang 71 mm (ETM772S) Ø71 mm body, 45 mm inside depth / 48 mm outer height 5 side knock-out inlets + 4 × Ø16 mm bottom knock-outs, with lid Centre bottom knockout for installation plug on plywood mould; EN IEC 60670-1, +90 °C casting
Precast concrete ceiling / roof box (6-way) ETM834S C-C 70 mm (M4), max. 15 kg load Type table H=83 mm (confirm cut-out & envelope via drawing on enquiry) 6 × Ø20 mm entries with locking springs & sealing plugs (no lid; ETM837S with lid) Pre-fabricated house factory concrete ceiling/roof candidate; PP, IP30, 850 °C glow-wire
Precast concrete multi-way connection box ETM931S C-C 67 mm Outer Ø75 / inner Ø57.5 mm, overall height 172 mm (body 131.4 mm) 6 × Ø20 mm + 1 × Ø25/20 mm entries with sealing plugs With BULO connection (ETM931S-1 without BULO); PP, IP30

To compare these models alongside our drywall and solid-wall families, open the interactive 26-model comparison table or review Centre distance 60, 67 or 71 mm: matching installation boxes to device systems.

2. Checkpoint One: Mould Fixing Interface (Steel Magnet, Plywood Plug, or BULO Holder)

In a precast plant, the box is only half of the mechanical system — the mould attachment holds the box against vibration and concrete flow. Verify which of the three documented fixing interfaces your line uses:

  • Magnet fixing on steel pallet tables: The ETM780S family (catalogue p. 40) is designed for fastening to steel moulds using magnets before pouring. Because magnet ring heights and inner tapers vary across magnet manufacturers, never assume a new box fits an existing plant magnet without a physical fit-check and trial pour.
  • BULO plastic holder interface: Catalogue tables distinguish variants with and without a BULO holder (for example ETM850S with BULO vs. ETM850S-1 without BULO, and ETM931S with BULO vs. ETM931S-1 without BULO). Specify the exact suffix on your drawing and purchase order.
  • Plywood formwork installation plug: On ETM750S (catalogue p. 53), an installation plug is used together with a screw or nail through the centre knockout in the bottom to fasten the box to a plywood mould. When the mould is stripped, the screw or nail follows the plywood formwork.

For practical tolerance and trial-casting procedures, read Positioning electrical boxes in precast concrete elements: tolerance, fixing and trial casting and Cast-in vs. post-installed boxes in precast walls.

3. Checkpoint Two: Conduit Entry Assemblies and Slurry Sealing up to +90 °C

High-frequency compaction and heat of hydration test every joint on a cast-in box. The Glob-el precast series is documented for installation into concrete with a maximum temperature during the casting process of +90 °C (working temperature −25 °C to +60 °C, installation temperature −5 °C to +25 °C). When auditing a second source, check three conduit details:

  1. Conduit diameter compatibility (Ø20 mm vs. Ø16/20 mm): ETM780S, ETM812S and ETM834S use Ø20 mm entries with locking springs and sealing plugs, whereas ETM784S uses a plugged 2ר16/20 mm top inlet (ETM788S). Note that 16 mm or 19 mm rigid/corrugated conduit used in the Netherlands cannot be forced into a dedicated Ø20 mm entry without risking cement slurry ingress (see Ceiling boxes for precast concrete).
  2. Twin-entry assembly count vs. pipe count in ETIM 9.0: On ETM780S (1 × 2ר20 mm inlet assembly ETM793S) and ETM812S (2 × 2ר20 mm inlet assemblies + cover ETM794S), align with your PIM team whether ETIM 9.0 feature EF003593 (Number of inlets) records the twin-entry assembly count or total pipe openings (ETIM 9.0 verification guide).
  3. Unused entry sealing: Confirm which inlets arrive factory-plugged and how unused openings remain sealed during vibration.

4. Checkpoint Three: Element Thickness, Rebar Cover and Dutch Lattice-Girder Slabs (Breedplaatvloer)

A catalogue designation of “concrete box” or “roof box for pre-fabricated house factory” does not automatically approve a model for every slab thickness, hollow-core slab or Dutch lattice-girder composite floor (breedplaatvloer). In a breedplaatvloer, the box and conduit routing must bridge the thin precast concrete shell (betonschil), lattice girders (tralieliggers) and the structural topping poured on site.

Existing Glob-el documentation lists ETM834S and ETM931S as catalogue precast ceiling/roof candidates and ETM780S, ETM784S, ETM812S as precast wall/element candidates, without a standalone Dutch breedplaatvloer certification. Always submit your element cross-section, rebar layout and mould fixing detail for engineering review before specifying a model. Dutch-speaking engineers can consult our dedicated guide Inbouwdoos voor breedplaatvloer: positionering, bevestiging en leidinginvoer (NL) and Inbouwdozen van de fabrikant (NL).

Frequently Asked Questions

What is the difference between ETM780S, ETM784S and ETM812S?

All three are precast concrete wall/element boxes with a 60 mm device screw centre. ETM780S (Ø71 mm, depth 60.5 mm) has one twin 2ר20 mm top inlet (ETM793S); ETM784S (Ø71 mm, depth 60.5 mm) has a plugged twin 2ר16/20 mm top inlet (ETM788S); ETM812S (drawing envelope 71 × 103 × 76 mm) carries two twin 2ר20 mm plugged inlet assemblies and cover ETM794S.

When should I choose C-C 70 mm (ETM834S) versus C-C 67 mm (ETM931S)?

Choose ETM834S (6-way roof box, catalogue table H=83 mm, M4 screws, max. 15 kg load) when your ceiling luminaire or cover accessory requires a 70 mm screw centre and six Ø20 mm side entries. Choose ETM931S (H=172 mm, 6ר20 mm + 1ר25/20 mm entries) when you need a deeper 7-way concrete connection box with a 67 mm screw centre and BULO mounting interface.

Can we request evaluation samples and controlled drawings for a trial element pour?

Yes. Qualifying a precast box almost always starts with a drawing cross-check followed by a trial casting on one pallet. Send your element thickness, conduit size and mould fixing method, and we will reply within 1 working day with controlled drawings and sample options.

Request Controlled Drawings, EPD / Compliance Files or Trial-Pour Samples

Share the models you are evaluating (ETM780S, ETM812S, ETM850S, ETM834S, ETM931S) or upload your current element drawing. Our engineering and sales desk replies within 1 working day.

Precast Concrete Plants Application Guide · Request Controlled Drawings or Trial Samples (1 Working Day Reply)