Concrete & Precast Boxes

Concrete and Precast Electrical Installation Boxes

Models for cast-in-situ formwork and factory-cast precast elements. Review positioning, fixing, conduit entries and concrete cover against the element drawing before quotation.

Technical family

Two concrete jobs, one review path

Precast plant and cast-in-situ work use different fixing logic. Tell us which process you are working in before choosing a model.

Precast plant

Boxes are placed into a mould during production of wall and floor elements. Position, fixing to reinforcement or mould face, handling and demoulding are reviewed together.

Cast-in-situ work

Boxes are fixed to formwork or held against a counter bearing. Attachment and conduit clearance relative to the reinforcement are the first questions.

Model records

Concrete and precast box range

Box records are shown first; related accessories are listed separately below. Technical fields follow the current model record.

ETM780S concrete precast box 45-degree product view

Concrete & Precast Boxes

ETM780S

ETM780S

Type: Box · Size / Depth: Ø71 mm body; depth 60.5 mm; drawing envelope 71 × 103 × 60 mm · Inlets: 1 × 2ר20 mm ETM793S inlet,…

ETM784S concrete precast box 45-degree product view

Concrete & Precast Boxes

ETM784S

ETM784S

Type: Box · Size / Depth: Ø71 mm body; depth 60.5 mm; drawing labels 71 × 104 × 75 mm; 32.5 mm side label · Inlets: Plugged ETM788S…

ETM812S concrete precast box 45-degree product view

Concrete & Precast Boxes

ETM812S

ETM812S

Type: Box · Size / Depth: Drawing envelope 71 × 103 × 76 mm; 30 mm side label · Inlets: 2 × 2ר20 mm plugged inlets · Material:…

ETM850S concrete precast box 45-degree product view

Concrete & Precast Boxes

ETM850S

ETM850S

Type: Box · Size / Depth: Outer Ø73.5 mm / inner Ø56.5 mm; CC 60 mm; overall height 123 mm; drawing labels 102.77 mm, 70.75 mm, 32 mm,…

ETM931S concrete precast box 45-degree product view

Concrete & Precast Boxes

ETM931S

ETM931S

Type: Box · Size / Depth: Outer Ø75 mm / inner Ø57.5 mm; CC 67 mm; overall height 172 mm; body height 131.4 mm; side dimension 85.4 mm…

ETM834S concrete precast box 45-degree product view

Concrete & Precast Boxes

ETM834S

ETM834S

Type: Box · Size / Depth: Ø83 mm body; depth 88.5 mm; CC 70 mm; H=83 mm · Inlets: 6 × Ø20 mm conduit inlets · Material: PP

The two accessory records are kept outside the concrete box model cards and are listed in the related accessories section.

Review checklist

What we check before recommending a box

  • Position and tolerance in the element
  • Fixing method and whether a counter bearing is available
  • Conduit entry size, direction and relation to reinforcement
  • Concrete cover and box orientation
  • Protection during casting
  • Demoulding and handling

From drawing to series supply

A controlled route into production

A trial element gives the plant a real installation result before a series decision is made.

  1. 01 · Drawing review

    Map the element

    Element type, wall thickness, reinforcement layout, electrical positions and fixing method.

  2. 02 · Sample casting

    Test the process

    Trial quantity for an actual element, not an assumption on paper.

  3. 03 · Confirmation

    Lock the details

    Confirm position, fixing, entries and protection against the trial result.

  4. 04 · Series supply

    Plan the line

    Match packaging units and call-off schedule to the production plan.

FAQ

Concrete project questions

Answers stay at process level until the exact model and plant setup are confirmed.

Can the boxes be fixed without a counter bearing?

Confirm the model-specific fixing method against the supplied product record and project drawing. Send the mould setup and we will confirm which box suits it.

Where should conduit entries sit relative to reinforcement?

That depends on concrete cover and the reinforcement layout. We work through it at drawing review.

How is the box protected during casting?

Construction protection keeps concrete and slurry out. Standard versus separately ordered protection is confirmed per model.

Can we test on one element first?

Yes. A trial quantity for one element is the normal first step for a precast project.

Next step

Send your element drawing

Element type, wall thickness, reinforcement layout, electrical positions, available fixing method and annual volume.